Skip to content
securitytabs

CVE-2026-116779

Critical9.8CISA KEV — exploited in the wild

FreeSWITCH: Inbound SIP MESSAGE can select the api chat proto and run FreeSWITCH API commandstitle from the CVE record

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.3, sofia_presence_handle_sip_i_message() split the To user of an inbound SIP MESSAGE on a plus sign and treated the left side as a chat protocol selector. Selecting the api chat proto reached switch_api_execute(), allowing a peer whose MESSAGE was accepted to run FreeSWITCH API commands, including operating-system command sinks, with the daemon's privileges. Inbound chat is enabled on the stock internal and external profiles, and any authenticated profile account is sufficient; stock directory users without password material can also remove that barrier in affected configurations. The flaw permits configuration and credential disclosure, arbitrary call control, and command execution, and exploitation has been observed in the wild. This issue is fixed in version 1.11.3.

CVSS
9.8v3.1
EPSS (exploit probability)
2.2%82th pct
CISA KEV
Listed
SecurityTabs reportupdated 16h agoCISA flags exploited flaws in IBM Aspera Faspex and FreeSWITCH

EPSS trendFIRST daily scores, last 90 days

FIRST EPSS rose from 1.3% on 2026-11-06 to 2.2% on 2026-11-10, ranging 1.3%–2.2% across 5 daily scores.
2026-11-06 → 2026-11-10 · 5 days · 1.3%–2.2%
Daily values
FIRST EPSS daily scores for this CVE
Score dateEPSSPercentile
2026-11-102.2%82.5%
2026-11-091.3%70.6%
2026-11-081.3%70.6%
2026-11-071.3%70.6%
2026-11-061.3%70.6%

CISA KEV entrycatalogue 2026.11.10

Date added
2026-11-09
Federal due date
2026-11-12
Known ransomware use
Unknown

Required action

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

Verbatim from the CISA KEV catalogue (CISA KEV, fetched 2026-11-11 15:43 UTC). The due date applies to US federal agencies under BOD 22-01.

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Learn

Why it happened and what stops it

Affected products

  • freeswitch freeswitch

Coverage2 articles

References

Facts sourced from NVD, FIRST EPSS, and CISA KEV. Last synced 2026-11-11 15:43 UTC.

  • CVSS & description: NVD 2.0, fetched 2026-11-09 21:43 UTC
  • EPSS: FIRST EPSS, fetched 2026-11-11 15:43 UTC; score date 2026-11-10
  • KEV: CISA KEV, fetched 2026-11-11 15:43 UTC